P0603
|
EEPROM
fault
|
INSTALL a new TCM |
|
P060A
|
Internal Control Module, Monitoring Processor Performance
|
INSTALL a new TCM |
|
P073E
|
gear R engagement blocking (after internal handling)
|
INSTALL a new transmission |
|
P073F
|
gear 1 engagement blocking (after internal handling)
|
INSTALL a new transmission |
|
P074A
|
gear 2 engagement blocking (after internal handling)
|
INSTALL a new transmission |
|
P074B
|
gear 3 engagement blocking (after internal handling)
|
INSTALL a new transmission |
|
P074C
|
gear 4 engagement blocking (after internal handling)
|
INSTALL a new transmission |
|
P074D
|
gear 5 engagement blocking (after internal handling)
|
INSTALL a new transmission |
|
P0791
|
In shaft 1 speed sensor defect, current out of range
|
INSTALL a new TCM |
|
P0792
|
Input
shaft speed 1 defect
|
INSTALL a new TCM |
|
P0847
|
Clutch 2 Pressure sensor voltage below normal operation voltage
|
INSTALL a new TCM |
|
P0711
|
Hydraulic, hybrid temperature sensor plausibility failure
|
INSTALL a new TCM |
|
P0715
|
Damper
speed sensor defect
|
INSTALL a new TCM |
|
P0766
|
CSMS1 / CSM1 sticks low / low oil level
|
CHECK for obvious oil leaks. CHECK the oil level and Test Drive. If symptoms persist INSTALL a new transmission |
|
P0771
|
CSMS2 / CSM2 sticks low / low oil level
|
CHECK for obvious oil leaks. CHECK the oil level and Test Drive. If symptoms persist INSTALL a new transmission |
|
P0796
|
Clutch 1 Plausibility Failure pressure too low
|
CHECK for obvious oil leaks. CHECK the oil level and Test Drive. If symptoms persist INSTALL a new transmission |
|
P2714
|
Clutch 2 Plausibility Failure pressure too low
|
CHECK for obvious oil leaks. CHECK the oil level and Test Drive. If symptoms persist INSTALL a new transmission |
|
P2715
|
Clutch 2 Plausibility Failure pressure too high
|
CHECK for obvious oil leaks. CHECK the oil level and Test Drive. If symptoms persist INSTALL a new transmission |
|
P0841
|
Clutch 1
Torque Plausibility Failure
|
INSTALL a new Clutch, if symptoms persist INSTALL a new TCM |
|
P0846
|
Clutch 2
Torque Plausibility Failure
|
INSTALL a new Clutch, if symptoms persist INSTALL a new TCM |
|
P2746
|
transmission path 2 speed plausibility error
|
INSTALL a new TCM |
|
P1905
|
EOL Mode
active
|
INSTALL a new TCM |
|
P0949
|
Teaching
not completed
|
Check for the latest TCM software level, Run Teach in routine using the
Ford diagnostic equipment.
|
|
P171A
|
shift fork 1 requested but movement on shift fork 2
|
INSTALL a new TCM
If symptoms persist INSTALL a new transmission
|
|
P171C
|
shift fork 2 requested but movement on shift fork 1
|
INSTALL a new TCM
If symptoms persist INSTALL a new transmission
|
|
P171D
|
shift fork 2 requested but movement on shift fork 4
|
INSTALL a new TCM
If symptoms persist INSTALL a new transmission
|
|
P171F
|
shift fork 3 requested but movement on shift fork 4
|
INSTALL a new TCM
If symptoms persist INSTALL
|
|
P172C
|
shift fork ½ movement in opposite direction (to left cylinder)
|
INSTALL a new TCM
If symptoms persist INSTALL a new transmission
|
|
P0581
|
SHSS1 current driver error: Short to Battery
|
INSTALL a new TCM |
|
P0798
|
CSPS1 valve current driver error: overcurrent
|
INSTALL a new TCM |
|
P2716/9
|
CSPS2 valve current driver error: overcurrent
|
INSTALL a new TCM |
|
P2720
|
CSPS2 valve current error: Short to Ground
|
INSTALL a new TCM |
|
P0964
|
CCFS current driver error Open load
|
INSTALL a new TCM |
|
P0979
|
SHCMS current driver error: Short to Ground
|
INSTALL a new TCM |
|
P0753
|
SHSS1 current driver error: Open load
|
INSTALL a new TCM |
|
P0778
|
CCFS current driver error: overcurrent
|
INSTALL a new TCM |
|
P0657
|
Common high side driver 1 not functional
|
INSTALL a new TCM |
|
P092C
|
Shift lock output short to Ground / Open Load
|
CHECK wiring for continuity, if symptoms persist INSTALL a new TCM |
|
P081B
|
Start lock output error: Short to Battery
|
CHECK wiring for short, if symptoms persist INSTALL a new TCM |
|
P283B
|
shift fork position 3 position range error (in counts)
|
INSTALL a new TCM |
|
P283D
|
shift fork position sensor 3 low output voltage failure
|
INSTALL a new TCM |
|
P2840
|
shift fork position 4 position range error (in counts)
|
INSTALL a new TCM |
|
P2842
|
shift fork position sensor 4 low output voltage failure
|
INSTALL a new TCM |
|
P2846
|
shift fork position sensor 2 neutral plausibility error
|
INSTALL a new TCM |
|
P2849
|
shift fork 1 blocked completely and no unexpected movement on other shift
fork
|
INSTALL a new transmission |
|
P284A
|
shift fork 2 blocked completely and no unexpected movement on other shift
fork
|
INSTALL a new transmission |
|
P284B
|
shift fork 3 blocked completely and no unexpected movement on other shift
fork
|
INSTALL a new transmission |
|
P284C
|
shift fork 4 blocked completely and no unexpected movement on other shift
fork
|
INSTALL a new transmission |
|
P284D
|
shift fork 1 movement but not requested
|
INSTALL a new TCM |
|
P284F
|
shift fork 3 movement but not requested
|
INSTALL a new TCM |
|
P2850
|
shift fork 4 movement but not requested
|
INSTALL a new TCM |
|
P0733
|
shift fork 2 jump out from forward towards the engine (left side)
|
INSTALL a new TCM
If symptoms persist INSTALL
|
|
P0734
|
shift fork 3 jump out from rearward towards the engine (right side)
|
INSTALL a new TCM
If symptoms persist INSTALL a new transmission
|