- 30 Окт 2006
Sony HMD-A200, HMD-A220 Diagnosis
Failure
Power LED
1. HV or +B Failure or H Stop
Blink Amber (On 0.5 sec, Off 0.5 sec)
2. V Stop
Blink Amber (On 1.5 sec, Off 0.5 sec)
3. ABL Failure
Blink Amber (On 0.5 sec, Off 1.5 sec)
4. Aging/Self-Test
Blink Amber (On 0.5 sec, Off 0.5 sec)
…Blink Green (On 0.5 sec, Off 0.5 sec)
Добавлено 30-10-2006 15:42
Sony CPD-420GS ch:D98 Self Diagnosis
Area of Failure
LED Indication
1. HV or B+
Orange 0.5s/Off 0.5s
2. H Stop, V Stop,Thermal
Orange 1.5s/Off 0.5s
3. ABL
Orange 0.5s/Off 1.5s
4. Aging/Self Test
Orange 0.5s/Off 0.5s Green 0.5s/Off 0.5s
Добавлено 30-10-2006 15:50
Nec FE750+ Error Codes:
1. High Voltage Error:
short0,5s flash 3s Long 2s flash 1s
2. Deflection Circuit Stop:
short0,5s flash 4s Long 2s flash 1s
3. Beam Protector:
short0,5s flash 5s Long 2s flash 1s
4. Heater Power Error:
short0,5s flash 6s Long 2s flash 1s
-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
External Control
INDEX
I. Application ……………………………………………………………………..4
II. Preparation …………………………………………………………………….5
2.2 LAN control …………………………………………………………………5
3.2 LAN control …………………………………………………………………7
4.3 Check code ………………………………………………………………..13
4.4 Delimiter ………………………………………………………………….14
5. Message type …………………………………………………………………15
5.3 Set parameter ………………………………………………………………18
5.5 Commands …………………………………………………………………20
5.5.3 NULL Message …………………………………………………………..22
IV. Control Commands ……………………………………………………………..23
7.1 Power status read …………………………………………………………..42
7.2 Power control ………………………………………………………………44
NEC LCD Monitor
(1/137)
Rev.1.0 (G2)
Summary of Contents for NEC LCD Monitor
-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
External Control
INDEX
I. Application ……………………………………………………………………..4
II. Preparation …………………………………………………………………….5
2.2 LAN control …………………………………………………………………5
3.2 LAN control …………………………………………………………………7
4.3 Check code ………………………………………………………………..13
4.4 Delimiter ………………………………………………………………….14
5. Message type …………………………………………………………………15
5.3 Set parameter ………………………………………………………………18
5.5 Commands …………………………………………………………………20
5.5.3 NULL Message …………………………………………………………..22
IV. Control Commands ……………………………………………………………..23
7.1 Power status read …………………………………………………………..42
7.2 Power control ………………………………………………………………44
NEC LCD Monitor
(1/137)
Rev.1.0 (G2)
Summary of Contents for NEC LCD Monitor
Appendix
Please inquire your dealer/distributor about action to be taken for each error code.
Error Code
4
GPSU(12V) Fail
5
Lamp Unlit
12
EEPROM R Fail
15
EEPROM W Fail
120
DLP Ack Fail
121
Lens Fail
138
ICP CriticalFail
139
ICP PowerOn Fail
141
DLP CommE Fail
151
Fan1 Stop
152
Fan2 Stop
153
Fan3 Stop
154
Fan4 Stop
155
Fan5 Stop
156
Fan6 Stop
157
Fan7 Stop
158
Fan8 Stop
159
Fan9 Stop
165
GPI MACRO(n) Selection Invalid
166
GPI Control Invalid
177
Tamper Fail
178
Marriage Tamper Fail
190
The Validity has expired.
191
Different Serial Number
245
Fan10 Stop
246
Fan11 Stop
247
Fan12 Stop
248
Fan13 Stop
249
Fan14 Stop
251
Fan1 Stop Precaution
252
Fan2 Stop Precaution
253
Fan3 Stop Precaution
254
Fan4 Stop Precaution
255
Fan5 Stop Precaution
256
Fan6 Stop Precaution
257
Fan7 Stop Precaution
258
Fan8 Stop Precaution
259
Fan9 Stop Precaution
264
Fan10 Stop Precaution
265
Fan11 Stop Precaution
266
Fan12 Stop Precaution
88
Error message
Description
Power supply is abnormal.
Lamp doesn’t light up.
EEPROM data read error is detected.
EEPROM data write error is detected.
ICP Firm failed operation.
Lens unit control error
ICP Firm Critical Error
ICP Firm Startup Error
Communication error with the ICP Firm
Fan1 has stopped.
Fan2 has stopped.
Fan3 has stopped.
Fan4 has stopped.
Fan5 has stopped.
Fan6 has stopped.
Fan7 has stopped.
Fan8 has stopped.
Fan9 has stopped.
Selection of preset button (n) through GPI is invalid because
metadata control is enabled.
* This message would be shown on Log, not on LCD.
Projector control through GPI is invalid because metadata
control is busy.
* This message would be shown on Log, not on LCD.
Service door tamper switch of projector is open.
Marriage tamper switch of projector is open.
The time limit for use of the projector has expired.
* In cases when the validity setting has been configured with
the projector
There is a mismtach in the serial number of the main unit
internally saved on the projector.
Fan10 has stopped.
Fan11 has stopped.
Fan12 has stopped.
Fan13 has stopped.
Fan14 has stopped.
Fan1 Stop Precaution
Fan2 Stop Precaution
Fan3 Stop Precaution
Fan4 Stop Precaution
Fan5 Stop Precaution
Fan6 Stop Precaution
Fan7 Stop Precaution
Fan8 Stop Precaution
Fan9 Stop Precaution
Fan10 Stop Precaution
Fan11 Stop Precaution
Fan12 Stop Precaution