German-made Jungheinrich loading equipment is distinguished by excellent durability and
performance. Benefit from consistently high handling speeds with maximum comfort. This European-quality equipment perfectly adapts to various operating conditions, meets strict safety standards,
is distinguished by high working and driving qualities for moving and storing goods for work both in an open area and inside a closed warehouse or a freight railway container.
Jungheinrich LPG trucks, like trucks from other brands of this type, have a number of advantages. This is a universal warehouse
equipment, which is very economical if, when buying it, you correctly calculate the basic requirements for the height of lifting of loads, carrying capacity, speed of movement, weight of the
machine, its dimensions and, of course, the types of cargo with which the machine has to deal. If the calculation is carried out carefully, and the optimal model is chosen, the costs for it,
given the low price of gas, will pay off in a few months. And due to its high ecological class, it can work on a shift all day long with practically different cargoes that require specific
transportation conditions. The peculiarity of gas forklifts is that you can start them in any weather without any problems, which can not be said about diesel or gasoline ones.
Jungheinrich electric forklift EFG 115
The EFG 115 is the most compact electric forklift from the German concern Jungheinrich. It can be used in the smallest rooms,
including wagons and wagons. It has the following technical characteristics:
The distribution of weight to the front axle is 3805/1270.
Carrying capacity — 1500 kg.
Total weight 2870 kg.
Engine:
running — 4 kW;
lifting — 6 kW.
The maximum speed is 12.5 km / h.
Clearance — 100 mm.
The wheelbase is 1200 mm.
The center of gravity of the load on the forks is 500 mm.
Mast tilt (a / b) in degrees — 5/6.
Mast — 2000-3550 mm.
Working corridor width:
across — 3114 mm;
along — 3236 mm.
The total width is 990 mm.
The total length is 2935 mm.
The service brake is hydraulic.
The maximum lifting height is 3000 mm.
The maximum climb is 16 degrees.
Fork dimensions (LxWxH) — 1150x100x35 mm.
Lifting speed with / without load — 240/500 mm / s.
Lowering speed with / without load — 580/600 mm / s.
It is worth noting that it is quite difficult to find a new Jungheinrich EFG 115 loader in the domestic market. However, these
forklifts are quite widely used, and here the price depends on the condition of the machine. In general, the cost can vary from 3,000 to 10,000 euros. The new EFG 115 will cost about 18,500
euros.
Electric forklift Jungheinrich EFG 215
The second series of EFG loaders differs from the first in a large set of technical options. All this could not but affect the cost, which will be
slightly higher than the 115 model. However, first, let’s look at the technical specifications:
The distribution of weight to the front axle is 3870/1310.
Carrying capacity — 1500 kg.
Total weight 2978 kg.
Engine:
running — 4.6 kW;
lifting — 11.5 kW.
Storage battery (voltage V / capacity kW * h) — 48/500.
The maximum speed is 16 km / h.
Clearance — 100 mm.
The wheelbase is 1249 mm.
The center of gravity of the load on the forks is 500 mm.
Mast tilt (a / b) in degrees — 7/7.
Mast — 2000-3560 mm.
Working corridor width:
across — 3104 mm;
Along — 3226 mm.
The total width is 1060 mm.
The total length is 2924 mm.
The service brake is electromechanical.
The maximum lifting height is 3000 mm.
The maximum climb is 35 degrees.
Turning radius — 1440 mm.
Fork dimensions (LxWxH) — 1150x100x35 mm.
Lifting speed with / without load — 460/600 mm / s.
Lowering speed with / without load — 550/550 mm / s.
As you can see from the technical characteristics, this car has almost the same dimensions as the previous model, but with more powerful motors and
improved other indicators.
Loading…
|
õUNGHEINRICH |
System Messages |
08.06 |
1 |
G |
|||||||
|
Error |
Description |
Component |
Display text |
Cause / Action |
Effect |
||||||
|
1 |
Low voltage during |
F, H, L, |
Low voltage |
Check battery voltage, chargebattery; |
Travel is inhibited. |
||||||
|
system start |
F-AC, H-AC |
Checkwireconnectiontocontroller; |
|||||||||
|
ELECTRICAL SYSTEM |
check main current fuse; check main |
Reduced power for |
|||||||||
|
contactor; replace control part; |
travel and lifting. |
||||||||||
|
Replacecomponent; |
Warning symbol |
||||||||||
|
(Limit VN = 80V: VBatt < 64V or |
flashing (Else-Check). |
||||||||||
|
VCap. < 56V |
|||||||||||
|
Limit VN = 48V: VBatt < 34V or |
|||||||||||
|
VCap. < 34V |
|||||||||||
|
Limit VN = 24V: VBatt <17V) |
|||||||||||
|
2 |
Overvoltage |
F, H, L, |
Overvoltage |
Check battery voltage; replace |
No travel or hydraulic functions |
||||||
|
F-AC, H-AC |
BATTERY |
controllerpart; replace component; |
Warning symbol |
||||||||
|
CONTROLLER |
(Limit VN = 80V: VBatt > 92 V |
flashing (Else-Check). |
|||||||||
|
Limit VN = 48V: VBatt > 62 V |
|||||||||||
|
Limit VN = 24V: VBatt > 28 V) |
|||||||||||
|
3 |
Temperature limit for |
F, H, L, |
TEMPERATURE |
Check sensor and wire connections |
Reduced power for |
||||||
|
controllers |
F-AC, H-AC |
CONTROLLER |
Allow controllers to cool down; check |
travel and lifting. |
|||||||
|
> 80°C (>70°C MP1510C) |
fan operation, improve cooling. |
Warning symbol |
|||||||||
|
or |
Warm up the controller and operate at |
flashing (Else-Check). |
|||||||||
|
ACS only: |
reduced level until the controller has |
||||||||||
|
Info at > 85°C |
warmed up. |
||||||||||
|
Err at > 115°C |
|||||||||||
|
Err at < -20°C |
|||||||||||
|
4 |
Emergency Disconnect |
F |
POWER SUPPLY |
Warning |
Brake applies, travel inhibited |
||||||
|
applied during travel |
(V < 20V MP1510C) |
|
õUNGHEINRICH |
System Messages |
08.06 |
2 |
G |
|||||||
|
Error |
Description |
Component |
Display text |
Cause / Action |
Effect |
||||||
|
5 |
Overvoltage |
F, F-AC, H-AC |
ELECTRICAL SYSTEM |
Check wire connection to battery, |
Brake applies, travel inhibited |
||||||
|
checkBattery, replacecontroller part; |
|||||||||||
|
Replace component; |
|||||||||||
|
(Limit for Retrak: VBatt > 62 V |
|||||||||||
|
Limit for MP1510C: V > 32 V) |
|||||||||||
|
6 |
Wire breakage: |
C, I2, I3, I4, I5, |
TRAVEL SWITCH |
Check wire connection; |
Travel stop. “Warning” symbol flashes |
||||||
|
— Travel setpoint device |
Travel switch |
Replace travel setpoint device; |
(Else-Check). Hydraulic functions |
||||||||
|
Replace Canion/ Interface; |
possible |
||||||||||
|
7 |
Key switch applied |
F,F-AC,H-AC |
KEY SWITCH |
Warning |
Brake applies, travel inhibited |
||||||
|
duringtravel |
(V < 13V for 200ms MP1510C) |
||||||||||
|
8 |
2 travel directions applied |
F-AC, H-AC, C, |
ELECTRICAL SYSTEM |
Warning, replace travel direction |
Travel stop. “Warning” symbol |
||||||
|
simultaneously |
MP, S, I2, I3, I5, |
switch, replace Interface 7 Canion; |
flashing (Else-Check). |
||||||||
|
FS |
replace Multipilot / Solopilot |
Hydraulic functions possible |
|||||||||
|
For twin pedal, check the electrical |
|||||||||||
|
system. |
|||||||||||
|
9 |
Operator protection switch |
I2, FS |
ELECTRICAL SYSTEM |
Check switch, check wire connections |
|||||||
|
faulty |
|||||||||||
|
10 |
V Cap. <> V Batt; (main |
F, H, |
MAIN CONTACTOR |
Check main contactor, check wire |
No travel, hydraulics |
||||||
|
contactor jammed or not |
F-AC, H-AC |
connection; check output pin 2 (ACS) of |
Warning symbol |
||||||||
|
open) |
L |
traction controller; replace component |
Flashing warning (Else-Check). |
||||||||
|
11 |
Offset error armature / |
F, H, L, |
CONTROLLER |
Check main current wire, replace |
Travel no function |
||||||
|
field current (DC) |
F-AC, H-AC |
component |
|||||||||
|
Stator current (AC); |
|||||||||||
|
Current measurement |
|||||||||||
|
point |
|||||||||||
|
12 |
Disable driver field |
F, H |
CONTROLLER |
Replace component; |
No travel, hydraulics |
||||||
|
rheostat faulty for DC |
F-AC, H-AC |
for AC: Check flat belt wire connection; |
Warning symbol |
||||||||
|
Disable driver power |
L |
replace power part |
Flashing warning (Else-Check). |
||||||||
|
stage faulty (forAC) |
|||||||||||
|
õUNGHEINRICH |
System Messages |
08.06 |
3 |
G |
|||||||
|
Error |
Description |
Component |
Display text |
Cause / Action |
Effect |
||||||
|
13 |
Disable Watchdog field |
F, H |
CONTROLLER |
Replace components |
Travel no function |
||||||
|
faulty |
|||||||||||
|
14 |
— Main contactor notclosed |
F, H, |
CONTROLLER/ |
Check wire connection; check main |
No travel, hydraulics |
||||||
|
— Field power stage cannot |
F-AC, H-AC |
MAIN CONTACTOR |
contactor; check charging connection, |
Warning symbol |
|||||||
|
be switched on (DC) |
Check field supply fuse, |
Flashing warning (Else-Check). |
|||||||||
|
Replace component. |
|||||||||||
|
15 |
Disable field faulty; |
F, H, |
CONTROLLER |
Replace controlpart; replace |
Travel no function |
||||||
|
Illegal address (for AC) |
F-AC, H-AC |
component |
|||||||||
|
L |
|||||||||||
|
16 |
Disable driver armature |
F, H, |
CONTROLLER |
Replace controlpart (AC); replace |
Travel no function |
||||||
|
actuator faulty; |
F-AC, H-AC |
component |
|||||||||
|
Software reset (for AC) |
|||||||||||
|
17 |
Disable Watchdog |
F, H |
CONTROLLER |
Replace components |
Travel no function |
||||||
|
armature faulty |
|||||||||||
|
18 |
DC: Armature power |
F, H, F-AC, H-AC |
CONTROLLER |
Check armature wire connection; |
Travel no function |
||||||
|
stage cannot be switched |
L |
replace power part; replace component |
|||||||||
|
on |
|||||||||||
|
AC: one of the 3 phases |
|||||||||||
|
cannot be switched on |
|
õUNGHEINRICH |
System Messages |
08.06 |
4 |
G |
||||||
|
Error |
Description |
Component |
Display text |
Cause / Action |
Effect |
|||||
|
19 |
Disable armature faulty; |
F, H, F-AC ,H- |
CONTROLLER |
Replace power part; Replace |
Travel no function |
|||||
|
Power stage short circuit |
AC, |
component. |
||||||||
|
(for AC) |
L-AC |
Can occur in connection with error 70, |
||||||||
|
The error may be |
in this case: |
|||||||||
|
triggered by the faulty |
check power supply behind the main |
|||||||||
|
speed sensor in |
contactor contact, in the event of an |
|||||||||
|
connection with |
error the voltage will be much lower |
|||||||||
|
AS4814Plus controllers. |
here than the rated operating voltage. |
|||||||||
|
Sensor wheel wobbles |
Disconnect the positive supply from the |
|||||||||
|
(elliptical) or the sensor- |
components to target the error cause. |
|||||||||
|
sensor wheel gap is too |
The exception here is the F1 traction |
|||||||||
|
big. In this case the |
controller which must remain |
|||||||||
|
component is not faulty. |
connected. One component overloads |
|||||||||
|
A short circuit cannot be |
the testing voltage due to internal short |
|||||||||
|
resolved by switching the |
circuit. |
|||||||||
|
truck off/on. |
The testing voltage arises by charging |
|||||||||
|
the internal capacitor batteries via a |
||||||||||
|
resistor to the level of the control |
||||||||||
|
voltage supply. |
||||||||||
|
Check sensor, replace sensor and / or |
||||||||||
|
sensor wheel. |
||||||||||
|
20 |
Armature incorrectly |
F, H |
ELECTRICAL SYSTEM |
Check armature main current wire |
Travel no function |
|||||
|
connected |
connection |
|||||||||
|
21 |
Armature overvoltage |
F, H, F-AC, H-AC |
CONTROLLER/ |
Check main current wire to armature; |
||||||
|
(short circuit / high side |
L |
ELECTR |
check settings(for AC); |
|||||||
|
faulty) |
AArmature > 360A for 250ms (MP1510); |
|||||||||
|
Replace component. |
||||||||||
|
õUNGHEINRICH |
System Messages |
08.06 |
5 |
G |
|||||||
|
Error |
Description |
Component |
Display text |
Cause / Action |
Effect |
||||||
|
22 |
Watchdog error; |
F, H, L, M, S, A, |
CONTROLLER/ |
Truck reset, |
No travel, hydraulics |
||||||
|
Watchdog does not run |
I2, I3, I4, C, |
CANION |
Replace controlpart; replace |
Warning symbol |
|||||||
|
out |
F-AC, H-AC, FS |
component |
Flashing warning (Else-Check). |
||||||||
|
23 |
— Computer overload |
F, H, L, M, S, A, |
CONTROLLER / CAN |
Check CAN bus connection; |
No travel, hydraulics |
||||||
|
— Permanent interrupt |
I2, I3, I4, C, |
Check CANION connector and |
Warning symbol |
||||||||
|
— “ACS” timeout on |
F-AC, H-AC, FS |
component; |
Flashing warning (Else-Check). |
||||||||
|
CAN connection |
Replace component |
||||||||||
|
24 |
EEPROM cannot be |
F, H, L, I2, I3, I4, |
CONTROLLER/ |
Check battery cable; check VBatt; set |
Flashing warning symbol (Else- |
||||||
|
contacted / parameters |
C, |
CANION |
trucktype, set default parameters; |
Check). |
|||||||
|
not plausible / parameter |
F-AC, H-AC |
replace control part; replace |
|||||||||
|
set to default |
MFC brake |
component |
|||||||||
|
Faulty checksum |
MFC hydr. , travel |
Delete logbook, change parameters, |
|||||||||
|
switch |
set hourmeter, replace component |
||||||||||
|
25 |
No telegrams: |
F, H, I4, I8 |
INTERFACE / CAN |
Check CANBus connection, check wire |
|||||||
|
— no logon from |
F-AC, H-AC |
connection between proportional valve |
|||||||||
|
interface |
L |
– modulation; check fuse 1F8; replace |
|||||||||
|
iInterface (I2, I4, I8) ; replace lift |
|||||||||||
|
potentiometer, Multipilot, Solopilot or |
|||||||||||
|
interface; |
|||||||||||
|
MP1510C: Voltage collapses, controller |
|||||||||||
|
logs on again, interface does not, |
|||||||||||
|
controller remains blocked and waits for |
|||||||||||
|
interface. |
|||||||||||
|
Check battery voltage (with load!); |
|||||||||||
|
charge or replace battery if necessary; |
|||||||||||
|
— no telegrams from |
AS2409K: no “live” telegram received |
||||||||||
|
from CAN Bus travel switch for more |
|||||||||||
|
Can-Bus travel switch |
than 300 ms; replace travel switch |
|
õUNGHEINRICH |
System Messages |
08.06 |
6 |
G |
|||||||
|
Error |
Description |
Component |
Display text |
Cause / Action |
Effect |
||||||
|
26 |
Wire breakage: |
M, S, I2, I3 |
MULTIPILOT / |
Check wire connection |
Lift stop. “Warning” symbol flashes |
||||||
|
— Lift potentiometer |
SOLOPILOT / LIFT |
(Else-Check), travel enabled |
|||||||||
|
POTENTIOMETER |
|||||||||||
|
27 |
Wire breakage: |
C, L, I3, I4 |
STEER ACTUAL |
Check wire connection; |
Crawl speed, |
||||||
|
— Steering setpoint device; |
ANGLE |
Replace steer angle sensor / |
Flashing warning symbol (Else- |
||||||||
|
◊ Reach truck: for 45° |
potentiometer; |
Check), hydraulic functions enabled. |
|||||||||
|
steering bolster movement |
Replace Canion / Interface; |
This error produces an emergency |
|||||||||
|
no flank from proximity |
Replace steering; |
stop on the reach truck and the |
|||||||||
|
switch. |
PM2402L from software version 1.60: |
Juniors. |
|||||||||
|
◊ Canion: “Steer angle |
|||||||||||
|
acquire active” parameter |
set parameter P511 “operating mode” |
||||||||||
|
has incorrect value |
correctly ◊ 1 = analog sensor |
||||||||||
|
◊ Juniors PM2402L: |
(potentiometer), |
||||||||||
|
“Operating mode” |
2 = digital sensor on steer motor |
||||||||||
|
parameter incorrectly set |
|||||||||||
|
28 |
Wire breakage: |
C, L, I3, I4 |
STEER NOMINAL |
Check wire connection, replace |
Crawl speed, |
||||||
|
— Steering sensor |
ANGLE |
steering wheel sensor;replace Canion / |
Flashing warning symbol (Else- |
||||||||
|
interface; replace steering |
Check), hydraulic functions enabled. |
||||||||||
|
This error produces an emergency |
|||||||||||
|
stop on the reach |
truck |
||||||||||
|
29 |
Wire breakage: |
M |
Traverse nominal value |
Replace Multipilot |
|||||||
|
— Traverse potentiometer |
MULTIPILOT |
||||||||||
|
30 |
Wire breakage: |
M |
Tilt nominal value |
Replace Multipilot, |
|||||||
|
— Tilt potentiometer |
MULTIPILOT |
Teach Multipilot (Hall sensor 2003 only) |
|||||||||
|
31 |
Wire breakage: |
M, S |
Sideshift nominal value |
Replace Multipilot / Solopilot, |
Hydraulic functions stop, “Warning” |
||||||
|
— ZH1 setpoint device |
MULTIPILOT / |
Teach Multipilot (Hall sensor 2003 |
symbol flashes (Else-Check), travel |
||||||||
|
SOLOPILOT |
only); |
enabled |
|||||||||
|
— Initial lift / lower |
Travel switch |
Travel switch: Check / replace switch |
|||||||||
|
Setpoint device |
|||||||||||
|
õUNGHEINRICH |
System Messages |
08.06 |
7 |
G |
|||||||
|
Error |
Description |
Component |
Display text |
Cause / Action |
Effect |
||||||
|
32 |
Wire breakage: |
M, S |
MULTIPILOT / |
Replace Multipilot / Solopilot, |
Hydraulic functions stop, “Warning” |
||||||
|
— ZH2 setpoint device |
SOLOPILOT |
Teach Multipilot (Hall sensor 2003 only) |
symbol flashes (Else-Check), travel |
||||||||
|
enabled |
|||||||||||
|
33 |
Wire breakage: |
M, I8 |
MULTIPILOT |
Replace Multipilot |
|||||||
|
— ZH3 setpoint device |
|||||||||||
|
34 |
CANBus damaged |
F, H, L, M, S, A, |
CAN-BUS |
Check CAN bus connection; |
No travel, hydraulics |
||||||
|
I2, I3, I4, I5, C, F- |
replace faulty component; |
Warning symbol |
|||||||||
|
AC, H-AC |
Check terminal resistances |
Flashing warning (Else-Check). Only |
|||||||||
|
Travel switch |
stored in logbook (from 2004). |
||||||||||
|
35 |
No travel zero position |
I2, I3, I4, C |
TRAVEL ZERO |
Warning, check travel switch; |
Travel stop, |
||||||
|
Deadman and accelerator |
Travel switch |
POSITION |
Intermittent contact in interface power |
Flashing warning symbol (Else- |
|||||||
|
pedal applied when truck |
supply (12 volts) |
Check), hydraulic functions enabled. |
|||||||||
|
switched on |
Check Canion, for twin pedal check |
||||||||||
|
electrical system |
|||||||||||
|
36 |
No lift zero position |
M, I2, I3,FS |
LIFT ZERO POSITION |
Warning, check lift setpoint device. |
Hydraulic functions stop, “Warning” |
||||||
|
symbol flashes (Else-Check), travel |
|||||||||||
|
enabled |
|||||||||||
|
37 |
No steering angle nominal |
L |
CONTROLLER / CAN |
Check steering setpoint device;Check |
|||||||
|
value |
CANBus connection; check “steer type” |
||||||||||
|
parameter; Replace component (I5) |
|||||||||||
|
38 |
Component does not log |
F, H, L, I2, I3, I4, |
CONTROLLER / CAN |
Check CAN-Bus connection and |
No travel, lifting |
||||||
|
on, self test not |
C, A, M, S, F-AC, |
voltage; check DIL switch 7 encoding |
Warning symbol |
||||||||
|
concluded. |
H-AC |
(MP1510); steering controller |
Flashing warning (Else-Check). |
||||||||
|
monitoring activated? (AS2412F); |
|||||||||||
|
check ACS encoding; replace |
|||||||||||
|
component |
|
õUNGHEINRICH |
System Messages |
08.06 |
8 |
G |
||||||
|
Error |
Description |
Component |
Display text |
Cause / Action |
Effect |
|||||
|
39 |
Implausible truck type |
F, H, L, I2, I3, I4, |
TRUCK TYPE |
For 1. Set truck type; |
||||||
|
1. Discovered during the |
I5, A, M, |
For 2. Examine and if necessary |
||||||||
|
self test phase that at |
F-AC, H-AC |
replace switch (key switch) or rectify |
||||||||
|
least one component |
intermittent contact in power supply |
|||||||||
|
has a different truck |
plug connections. |
|||||||||
|
type as a parameter. |
Set truck type. |
|||||||||
|
A different truck type was |
||||||||||
|
discovered in operating |
||||||||||
|
mode. Caused by |
||||||||||
|
intermittent contacts in the |
||||||||||
|
power supply connections |
||||||||||
|
40 |
Motor overtemperature |
L, F, H |
TEMPERATURE |
Warning; check motor sensor system |
Reduced power for |
|||||
|
Traction motor |
F-AC, H-AC |
MOTOR |
and wire connections; |
travel and lifting. |
||||||
|
overtemperature in |
Check motor; traction motor brake |
Warning symbol |
||||||||
|
operating mode.> 150°C |
open? |
flashing (Else-Check). For steering |
||||||||
|
And travel speed < 1km/h |
only |
|||||||||
|
For ACS: |
warning symbol flashing. |
|||||||||
|
Info > 145°C |
||||||||||
|
Err > 165°C |
||||||||||
|
41 |
Brake magnet |
L |
BRAKE |
Check potentiometer; check |
||||||
|
potentiometer |
MAGNETPOTENTIOM |
potentiometer attachment; check wire |
||||||||
|
Potentiometer voltage less |
ETER |
connection |
||||||||
|
than 0.3 volts or greater |
||||||||||
|
than 2.7 volts for more |
||||||||||
|
than 500ms. |
|
õUNGHEINRICH |
System Messages |
08.06 |
9 |
G |
|||||
|
Error |
Description |
Component |
Display text |
Cause / Action |
Effect |
||||
|
42 |
— Short circuit between |
L,F |
BRAKE MAGNET |
Check wire connection, check brake |
|||||
|
the output and battery |
magnet; replace component |
||||||||
|
positive.(EJC, ELE) |
|||||||||
|
-Brake magnet control, |
|||||||||
|
below minimum difference |
|||||||||
|
on potentiometer for 500 |
|||||||||
|
ms when magnet applied. |
|||||||||
|
(150mV ) |
|||||||||
|
No brake pressure during |
|||||||||
|
initialization. |
|||||||||
|
Brake pressure after the |
|||||||||
|
Emergency Stop magnet |
|||||||||
|
has applied; |
|||||||||
|
43 |
Adjust brake |
L |
ADJUST BRAKE |
Adjust brake; check potentiometer |
|||||
|
44 |
—Brake not connected or |
L,F |
BRAKE FAULTY |
-Check brake wiring, replace brake if |
No release |
||||
|
connection wire short |
necessary |
||||||||
|
circuit |
-Replace brake cable, check |
||||||||
|
potentiometer; Check potentiometer |
|||||||||
|
-Brake cable torn |
attachment; |
||||||||
|
Only for steer category_3: |
Only for steer category_3: |
||||||||
|
Internal driver of failsafe |
|||||||||
|
brake cannot connect the |
-Check brake driver output, check |
||||||||
|
relay |
switch contact plausibility, |
||||||||
|
Or short circuit bypass |
Replace steer component. |
||||||||
|
(contact jams) on the |
|||||||||
|
output during power up |
|||||||||
|
test |
Jungheinrich EFG 220 и другие модели этой серии оснащены трехфазным двигателем переменного тока, который представляет собой стандарт качества новой современной складской техники. Данный тип электродвигателя позволяет погрузчикам:
- экономить энергию. Энергия высвобождается за счет функции рекуперации. Оптимальный КПД обеспечивает хорошую работоспособность;
- сократить затраты на ТО;
- повысить производительность погрузчиков, которая достигается за счет трехфазового питания электродвигателя.

Электропогрузчик Jungheinrich EFG 220
Конструктивные особенности вилочных погрузчиков Jungheinrich EFG:
- Одного заряженного аккумулятора хватает на продолжительное количество времени работы, за счет этого складская логистика увеличивает рабочий цикл. Срок окупаемости снижается за счет сокращения расходов на топливо и техобслуживание. Аккумуляторные батареи заменяются так же быстро, как заправляется автомобиль на заправочной станции. Заменить батарею можно тремя способами в зависимости от загруженности склада и погрузчика. Вилочные электропогрузчики Jungheinrich с легкостью могут работать в несколько смены. Также к плюсам нужно отнести отличную современную и прочную конструкцию, сниженные до минимума затратчы. В создании моделей погрузчиков использовались новейшие технологии.
- Прочность конструкции обусловлена повышенной защитой освещения, прочными металлическими стенками и крышками
- Безопасность и устойчивость техники достигается за счет цельнометаллического корпуса и отсека под батарею.
- Все электропогрузчики Jungheinrich оснащены механизмами не требующими технического обслуживания.
- Погрузчики оснащены светодиодными модулями для подсветки работы, а также галогенными лампами для освещения (могут не устанавливаться по просьбе заказчика).
Основные характеристики

Вилочный погрузчик Jungheinrich EFG 220
- Телескопическая мачта, которой оснащены все электропогрузчики, может поднять груз на высоту до 6,5 м в зависимости от модели погрузчика. Также в зависимости от модели грузоподъемность варьируется от 1,3 тонн до 2 тонн включительно (Jungheinrich EFG 213 — 1,3 тонны, Jungheinrich EFG 220 — 2 тонны и т. д.).
- Повышенная маневренность достигается за счет электропривода рулевой колонки.
- Тормоз стоянки срабатывает автоматически, что также увеличивает комфорт в эксплуатации погрузчика.
- Электропогрузчик имеет пять индивидуальных программ работы, которые в свою очередь могут быть адаптированы под любого оператора и любую работу.
- Новшеством в управлении погрузчиком стали две системы: система SOLO и система MULTI-PILOT, которые вмонтированы в подлокотник кресла водителя.
- Рычаги управления вилочным электропогрузчиком находятся в удобном местоположении.
Преимущества электропогрузчиков серии EFG
Кабина оператора. Эргономичность и удобство

Jungheinrich EFG 220. Рабочее место оператора
В кресле оператора водитель электропогрузчика будет чувствовать себя комфортно и не устанет даже после долгой рабочей смены:
- Рулевой электропривод позволяет с легкостью управлять электропогрузчиком в любых условиях.
- Гидравлика полностью отсутствует в конструкции погрузчиков и позволяет установить более удобную кабину оператора. Оператор получает большую свободу для ног, плюс ко всему снижается уровень шума.
- Одним из нововведений, используемым в машиностроении, стало оснащение рулевой колонки, теперь ее можно регулировать по высоте и углу наклона.
- Рычаги управления, буквально все, встроены в подлокотник кресла оператора, подлокотник имеет степень регулировки по длине и высоте.
- Вибрационные процессы, идущие от основной оси, демпфируются (гасятся). В конструкции электропогрузчика использована так называемая «плавающая кабина».
Система энергоконтроля
- Рекуперативные функции погрузчика выполняются за счет трехфазного электродвигателя и тормозов. Это повышает показатель КПД погрузчика и увеличивает продолжительность работы до замены батареи.
- Заменить батарею можно с помощью тележки, штабелера или крана, при условии, что они производства Jungheinrich.
- Батарейный отсек расположен сбоку, что облегчает процесс подзарядки батареи.
- При техническом обслуживании облегчена доступность к механизмам.
- Установлено зарядное устройство с двумя классами мощности. Это позволяет ускорить процесс подзарядки аккумуляторной батареи.
Система торможения
Система тормозов погрузчика выполнена из износоустойчивых материалов и позволяет ровно и плавно тормозить:
- Тормоза на основной оси не требуют ТО.
- При остановке электропогрузчика используется торможение, осуществляемое при помощи педали акселератора.
- Находясь в наклонной плоскости, срабатывает система стояночного торможения.
- Диски в системе торможения не требуют ТО.
Двигатель электропогрузчика
Двигатели Jungheinrich могут использоваться в любых условия и при любой нагрузке. Работают исключительно с повышенной производительностью и пониженной шумоотдачей
- Даже на малых оборотах двигатель имеет высокий крутящий момент.
- Механизмы двигателя смазываются автоматически за счет специальной автоматической системы.
- Конструкция электропогрузчика оснащена двумя раздельными электродвигателями.
- Класс защиты всех компонентов конструкции электропогрузчика приравнен к IP 54.
Система безопасности
Электропогрузчики Jungheinrich серии EFG оснащены множеством элементов безопасной работы, это стало необходимым, так как вилочные электропогрузчики обладают повышенной мощностью и отличной маневренностью:
- Автоматическая система блокировки всех процессов, если оператор покинул кабину.
- Электропогрузчики оснащены системой автоматического торможения при наклонной плоскости и выключения двигателя.
- Jungheinrich Curve Control – система, обеспечивающая сокращение скорости движения при вхождении в поворот.
- Электронный дисплей в кабине оператора отображает скорость электропогрузчика, набранную при движении.

Jungheinrich EFG 220. Кабина оператора
Место оператора имеет несколько систем безопасности, в частности это:
- Система доступности управления погрузчиком Access Control. Система в порядке очереди проверяет: код доступа, нахождение оператора в кресле и пристегнут ли он ремнем безопасности.
- Система Drive Control, снижающая скорость на поворотах.
- Система Lift Control обеспечивает контроль за скоростью движения телескопической мачты.
«Умная» электроника
- Высокоточное перемещение на нужное расстояние.
- Адаптивность к различным условиям работы за счет многозадачности программного обеспечения.
- Электропогрузчик запоминает выполненные процессы и ошибки в памяти, тем самым сокращается время простоя техники при ТО.
- Рулевое колесо и скорость движения фиксируются при базовом исполнении.
Основные преимущества
- Эргономичное и удобное место работы оператора.
- Тормозная система на основной оси не требует замены и техобслуживания.
- Нововведения в системе безопасности груза и оператора электропогрузчика.
- Современная система экономии энергии.
- Двигатели Jungheinrich электрического исполнения не требуют ТО.
- Высокоинтеллектуальная система управления и контроля.
Инструкция по эксплуатации Jungheinrich 213, 215, 216k, 216, 218k, 218, 220 — instruction-efg-213-200.pdf
-
15.03.2018
-
13.03.2018
-
9.10.2017
-
29.08.2017